90° Atex Adaptor – (AR-D Series)
Redapt AR-D Series of 90° Adaptors are designed to provide a method of facilitating cable entry, through a cable gland or conduit, where space limitation precludes conventional entry.
The design also provides protection for the cable which may be subjected to increased bending stress during installation.
The AR-D Series also serves as a method for matching different electrical threadforms on hazardous area approved equipment whilst ensuring the integrity and Ex approval of the installation is maintained.
They are available with either Male x Female or Female x Female connection threads and can also be used to adapt or reduce the entry thread size of the enclosure or equipment.
Redapt 90° Adaptors are designed for hazardous area applications and are certified to protection concept Exd “Flameproof” for use in Zone 1 and Zone 2 applications.
Approved to the latest international
standards, 90° adaptors can be supplied with ATEX (CENELEC), IECEx, and
GOST-R hazardous area certificates.
Protection Method | Exd – Flameproof |
---|---|
Ingress Protection Maintained | IP64 |
Impact Resistance | 7Nm |
Ambient Temperature Range | -50°C to 180°C |
Threadforms | ISO Metric, NPT, PG, NPS, BSPP, BSPT, ET. Others on application |
Materials | Brass CZ121, 316 Stainless Steel, Aluminium 6082, Mild Steel EN1A |
Plating | Nickel, Electroless Nickel, Zinc, others on application |
Standards Approved To | IEC 60079-0, IEC 60079-1, IEC 61241-0, IEC 61241-1 |
ATEX Approval | SIRA99ATEX1195U |
IECEx Approval | IECExSIR12.0016X |
GOST-R Approval | RU ?-GB.??06.?00106 – Russian RU ?-GB.??06.?00106 – English RU ?-GB.??06.?00106 Annex document – English |
CSA Approval | 1248014 (LR 106084-2) |
In addition CSA approval certificates can be supplied to cover use in North American and Canadian Class I Division 1 and Class I Zone 1 applications.