KA 2000 – Atex Classic Sensor

Capacitive Sensors- StEx – ATEX

  • For use in area with the risk of dust explosion, zone 20.
  • For use in area with the risk of gas explosion, zone 1.
  • Housing material: Stainless steel VA, No 1.4503 (AISI 303)
  • Welding sockets and Varivent adapter available for EHEDG conform mounting.
Technical data
Level sensor, in contact with the productMedium dependent adjustable
Operating distance min / max adjustable0.5..15 mm
Electrical version4-wire DC
Output functionantivalent
Type PNP CurrentKAS-80-A23-A-G1/2-PEEK/VAb-Z03-1-2G-1/2D
Type PNPKAS-80-M23-A-StEx
Part. NoKA 2000
Operating voltage10…30 V DV
Voltage drop max< 2.0 V
Permiec residue ripple max10%
Operating current2 x 0…150 mA
No-load currentTyp. 15 mA
Frequency of operating cycles max.50 Hz
LED-displayGreen / Yellow
Protective circuitBuilt-In
Degree of protection IEC 60529IP 67°
NormEN 60947-5-2
Connection cable3 m, PVC, 5 x 0.14 mm²
Housing materialStainless Steel VA No 1.4305 / AISII 3030 (FDA confirming)
Active SurfacePTFE (FDA 21 CFR 177.2415)
LidPC (FDA 21 CFR 177.1580)
Media optimiazedYes
AccessoriesVarivent Adapter part no 196395. Welding Socket part no. 196394
Social media & sharing icons powered by UltimatelySocial