Horizontally Mounted Hazardous Area Float Switch for Intrinsically Safe Systems (HFS FP)

Product Description

The HFS FP intrinsically safe switch is a horizontal magnetic float switch for control and indication of a liquid level whilst in a potentially explosive atmosphere. Manufactured in 316L Stainless Steel, it is a horizontally mounted Liquid Level Sensor ideally suited to high temperature or pressure operation. It is also suitable for harsh environments and chemically aggressive liquids. It can be changed from Normally Open to Normally Closed operation to allow for sensing of high or low conditions by rotating the orientation of the body through 180°.

Refer to certificate ExVeritas 14ATEX0427X for clarification of system suitability and conditions for safe use. This switch must be used in conjunction with an intrinsically safe barrier when used in a potentially explosive atmosphere.

Download the Datasheet here: HFS-FP Datasheet and Certificate

Technical data and ATEX coding

HFS FP-xxx-01/02

Ex II 1G IIC T4/T6 Ga
Ex II 1D IIIC 135°C/85°C Da
-20°C≤Tamb≤+100°/+60°C

HFS FP-xxx-02DIN

Ex II 1G IIA T4/T6 Ga
Ex II 1D IIIA 135°C/85°C Da
-20°C≤Tamb≤+100°C/+60°C

Minimum Liquid Specific Gravity0.9
Maximum pressure350psi  24bar
Ambient and liquid Temperature-20°C to +100°C-20°C to +60°C in Gas T6 / Dust T85°C environment
Switch contact RatingFormA: <240V*, 1A*, 50Watts* MAXFormC: <175V*, 500mA*, 10Watts *MAX*Maximum safety barrier ratings apply when used in hazardous area
Cable type1 Metre PTFE insulated 7/0.2mm3 Metre on request
Cable coloursForm A:
2x Blue
Form C:
Violet:  Common
Yellow: Normally open
Blue: Normally closed
MountingM16 internal mount3/4” NPT external mount
Wetted Materials316L Stainless Steel